THE GREATEST GUIDE TO PERKIN ELMER AUTOSAMPLER

The Greatest Guide To perkin elmer autosampler

The Greatest Guide To perkin elmer autosampler

Blog Article

Mixing by aspiration—mixing of sample by aspiration in place of shaking makes certain homogeneity with the sample and maintains cell viability

The CytKick Max Autosample features a Improve manner that permits quicker sample processing, and passive cooling for a few plates/racks. A CytKick Max Accent Package is included that contains 4 accent plates: two cooling plates and two tube adaptors, in addition to a Max dongle crucial. A computer just isn't provided with the autosampler considering that a person is provided with the cytometer.

To avoid probe crashes, which may have to have expensive probe replacement, the CytKick Max Autosampler routinely performs a probe self-calibration to aid assure constant positioning in the probe in each individual nicely. The self-calibration verifies appropriate function of the probe, minimizes variability in probe positioning after a while to avoid failures through plate operates, and will help increase dependability above the life of the process.

Compared with other plate loaders that blend samples by shaking, which can not guarantee homogeneity on the sample, the CytKick Max Autosampler mixes samples by aspiration and stirring, enabling uniform mixing when preserving sample viability and leading to constant data with CVs a lot less than 10% across the plate. The CytKick Max Autosampler also has a delicate combine manner for fragile mobile lines.

The autosampler’s indicator lights and warning systems are actually made to make certain a user who has walked far from the system can certainly begin to see the method standing all the time.

To take care of program adaptability, the guide sample probe is often accessible even though the loader is present, and switching in between tubes and plates is detected by using software package and isn't going to involve added user intervention.

The CytKick Max Autosampler was meant to lessen system down time. Automatic sampling devices in many cases are suffering from clogging or probe crashes. The Clever Probe, which has a two hundred-micron diameter which is larger than most probes readily available within the field, minimizes occasions of clogging.

The intuitive computer software lets fast Mastering and information Assessment. Such as, a heat map look at will allow speedy screening and affirmation of samples while the instrument is obtaining facts.

Easy transition—no disassembly, no added QC, no reboot demanded for conversion in between plates and tubes

The CytKick Max Autosampler has two choices for processing samples inside of a higher-throughput setting: substantial-throughput manner and Increase mode.

Self-calibration of your probe also allows the autosampler to be effortlessly moved, so it may be shared among several instruments.

The instrument design and style and application have been designed with buyer simplicity-of-use in your mind. The CytKick Max Autosampler has fluidic bottles with sensors that notify the user when the fluids need to get replaced.

Autocleaning of autosampler is completed throughout the instrument shutdown procedure for that reason no supplemental consumer measures are essential to maintain system.

Setting up an experiment with the Attune NxT cytometric program is easy. Using perkin elmer autosampler a plate layout view, people can generate compensation wells, determine instrument options, and determine samples.

Report this page